top of page
Sustainable Designs, Reliable Solutions

Healthcare

Capture_edited.jpg

Kaiser Permanente

South San Francisco, CA

​

1.     Kaiser Hospital in south san Francisco (SSF)- Providing Mechanical Infrastructure Study for the existing major mechanical equipment in the Low-Rise Hospital Tower, Medical Office Building (MOB), and Orchid Center. The hospital is under OSHPD jurisdiction.  

​

2.    MEP Tenant improvement for miscellaneous renovation for the hospital and medical office building.
 

Kaiser  Permanente

2425 Geary Blvd., San Francisco, CA

​

Mechanical, Electrical and Plumbing Design. This was a remodel for an existing Cath Lab #3 for new equipment- Reviewed by OSHPD. 

​

New Kaiser Emergency Department
Richmond, CA

 

Complete Mechanical, Electrical and Plumbing system design for a new Emergency Department in Richmond California.

​

11,000 SF

WalnutCreek_Hospital1_Banner.jpg

John Muir Mt. Diablo Health System

Walnut Creek, CA

​

Completed mechanical and plumbing design services for this 4-story, new hospital building.  The facility will include Central Sterile, Material Handling, MRI, Cath. Lab, OR’s, Radiology, ICU/CCU and Med. Surg. Patient Rooms. 

​

95,000 SF

Kaiser Permanente 
Hayward, CA


1.    Oncology Department- Tenant improvement for remodeling the entire Oncology Department on second floor to add patient station. Reviewed by OSHPD and under construction.

2.    Respiratory Department- Tenant improvement for remodeling the respiratory Therapy Pulmonary Function department. Reviewed by OSHPD. 

El Camino New Hospital- 450 bed
Mountain View, CA

​

Complete Mechanical System Design for new hospital. The new building accommodates 450  beds and an emergency room/department. The building also includes an observation unit, a conference center, 16 operating/interventional treatment rooms, a multi-track emergency department and flexible nursing modules.

​

488,000 SF

Kaiser%20San%20Rafael_edited.jpg

Mills Peninsula Hospital 
Burlingame, CA

​

Mechanical, Electrical and Plumbing Engineering for:


1.    Gama Camera room- Complete remodeling of the medical equipment in Gama Camera room and associated mechanical system. D.

​

2.    Dialysis Installation in Patient Room 2429- Modify existing Mechanical system to incorporate the addition of the Dialysis unit for patient room 2429. 
 

Kaiser Permanente

San Rafael, CA

​

San Rafael at the corner of Third and A street- square feet of new medical office building (MOB). Complete mechanical system design for three story medical office building. Complete construction in 1990. The MOB includes; Internal Medicine, Eye Care, Dermatology, Cosmetic Services, Nephrology, Pharmacy, Laboratory and Radiology.

​

40,000 SF

Kaiser Medical Center, Building 1 & 2-
3900 Broadway,  Oakland, CA

 

Mechanical, Electrical and Plumbing Engineering for:

​

1.    Building #1- Replacing the entire existing mechanical system with new for the two-story medical office building approximately 15,000 square feet. Construction completed in 2015.


2.    Building #1- Replacing the entire existing mechanical system with new for the two-story medical office building approximately 15,000 square feet. Construction completed in 2015.
 

kindred.png
grant cuesta.jpg

Kindred Hospital
San Leandro
, CA

 

​A&S provided mechanical, electrical and plumbing engineering design services for Kindred Hospital in San Leandro, California. The scope of work for this project includes the replacement of the existing custom built 100% outside air handling unit in the basement and associated exhaust fan on the roof. The square footage size is 15,000 and the cost is $1.8 million. The scope of work also includes the controls for the air handling system and associated exhaust fan. The proposed new air handling unit is a custom-built, multi-zone unit serving miscellaneous zones in the surgery suite and zone controls are via re-heat coils.

​
 

Grant Cuesta Sub-acute and Rehabilitation Center
Mountain View
, CA

 

Grant Cuesta Sub-acute and Rehabilitation Center is a nursing home with short-term and long-term residency. The scope of work involved the replacement of two 100- Gallon water, one domestic hot water with two high-efficiency 100 gallon, 250,000 British Thermal Units per Hour (btuh) hot water heater. These hot water heaters are serving the kitchen, laundry and patient care areas. The scope also involved one HVAC boiler with one high-efficiency condensing boiler. The boiler is serving the radiant floor heating and all manifold piping zones are existing. A&S provided Mechanical and Plumbing Engineering for this HCAI approved project.

​
 

windsor.jpg

Windsor Nursing and Care Centers
Various Locations -Northern California

 

A&S Engineers worked with the Architect and design team to provide tenant improvement services for Windsor Nursing and Care Centers at various locations throughout Northern California including, Carmichael, Pleasant Hill and Stockton. The scope of work was to replace the gas fired boiler to two smaller gas fired water heaters as well as replace the failing water heater. We designed the hot water heater replacement and a new high temperature alarm at the nurse station to be connected to the Essential Electrical System (EES). We reviewed the HCAI review comments and drawings and are prepared the final Construction Documents.

​
 

bottom of page